Industrial Electrical Services · Pillar Guide
NFPA 70E compliance inspections, arc flash assessment, OSHA verification, infrared thermography — findings documented, prioritized, and actionable.

Industrial electrical safety has gotten more rigorous over the last decade. OSHA enforcement of NFPA 70E (Standard for Electrical Safety in the Workplace) has expanded; insurance carriers increasingly require documented compliance; arc flash incidents drive both regulatory attention and litigation exposure. The result: industrial facilities now need formal electrical safety programs, with regular inspections to verify compliance and identify hazards.
We do industrial safety inspections both as standalone engagements (for facilities establishing or updating their electrical safety program) and as part of maintenance contracts (where periodic inspection is included in the contract scope). The inspections are most valuable when they drive corrective work — facilities that document findings, prioritize remediation, and track progress achieve real safety improvements.
'Industrial electrical safety inspections' cover compliance and condition assessment work for production facilities — including NFPA 70E program review, arc flash hazard assessment, OSHA compliance verification, and infrared thermography for predictive maintenance.
NFPA 70E is the consensus standard for electrical safety in the workplace — covering employee training, PPE requirements, work practices, equipment labeling, and the electrical safety program documentation. OSHA enforces compliance with NFPA 70E through general duty clause and specific standards (1910.331-.335).
Arc flash hazard assessment calculates the incident energy (cal/cm²) at each piece of electrical equipment — driving PPE requirements and equipment labeling. Performed by licensed engineers using software like ETAP or SKM. Results in stamped engineering report, labeling at each piece of equipment, and recommendations for mitigation where energy levels are excessive.
For the broader context this guide supports, see our Industrial Electrical Services overview.
Safety inspection work organizes by inspection type and by regulatory framework.
Three guides to read first
What an NFPA 70E inspection covers, what gaps look like, and how the program documentation works.
Explore the guide →The arc flash study process — field data collection, engineering analysis, labeling, mitigation recommendations.
Explore → PredictiveHow thermal imaging identifies impending failures — what it finds, how often it should happen, finding follow-through.
Explore →Browse the Full Library
Different inspection types serve different purposes. Most industrial facilities need a mix of all four over a typical 3-5 year cycle.
Reviews the facility's electrical safety program documentation — training records, work practice procedures, PPE inventory, equipment labeling consistency. Typically annual; gaps documented with corrective action recommendations.
Engineering analysis calculating incident energy at each piece of electrical equipment. Typically 5-year cycle (updated when major distribution changes happen). Results in stamped report and equipment labeling.
Thermal imaging of panels, MCCs, transformers, motor connections to identify hot spots indicating impending failures. Typically quarterly or annual depending on facility criticality.
Comprehensive electrical condition assessment for insurance carrier renewal. Carriers increasingly require current inspection documentation; non-compliance affects premium or renewal.
Inspections without follow-through deliver no actual value. We've seen facilities where inspection reports sit on shelves for years while the documented hazards remain — and then become liability exhibits when an incident happens. The pattern: inspection identifies findings, facility schedules corrective work, work gets completed and documented, next inspection verifies completion and identifies new findings. Real safety improvement requires the full cycle.
We treat inspection findings as the start of a workflow, not the end. Every inspection we perform comes with: written findings ranked by criticality (immediate hazards, near-term corrective work, monitoring items), recommended corrective scope with cost estimates, and a follow-up schedule. For facilities we have ongoing maintenance contracts with, we track corrective work completion in our documentation and verify at the next scheduled visit.
Arc flash assessments produce specific deliverables that drive ongoing safety work.
Licensed engineer's calculation of incident energy at each piece of equipment, working distance assumptions, PPE category required, and any recommendations for mitigation. Becomes part of the facility's permanent electrical documentation.
Each piece of electrical equipment gets a label showing the incident energy, required PPE category, and working clearance. Required by NFPA 70E and OSHA enforcement.
Where incident energy is excessive (typically above Category 4 PPE threshold), the assessment recommends mitigation: arc flash relays, faster overcurrent protection, equipment replacement, or remote racking provisions. Recommendations prioritized by hazard level.
Inspection costs vary with facility size and scope. Typical 2026 Marin/Sonoma pricing for industrial inspections.
| Inspection type | Typical facility scope | Cost range | Cycle |
|---|---|---|---|
| NFPA 70E program review | Small light-industrial | $3,200-$6,800 | Annual |
| NFPA 70E program review | Medium industrial | $6,500-$12,500 | Annual |
| Arc flash assessment | Small light-industrial | $4,800-$9,500 | 5-year |
| Arc flash assessment | Medium industrial | $9,500-$18,000 | 5-year |
| Infrared thermography | Per inspection visit | $1,200-$3,400 | Quarterly/annual |
| Pre-insurance inspection | Comprehensive | $3,800-$8,500 | Per renewal |
This guide reflects Towery Electric's professional standards as a California-licensed C-10 electrical contractor and is for general information. Site conditions, panel configurations, code amendments, and permit-authority requirements vary; final scoping, sizing, and code compliance for your specific address are determined on a paid site assessment. We follow California Electrical Code (Title 24, Part 3) and applicable NFPA 70 (NEC) editions adopted by your AHJ.
Fill out the form below and we'll get back to you within 24 hours.